Discover our 1300°C Rapid Thermal Process for dynamic traction. Our engineering expertise in heating, atmosphere management, vacuum management, mechanical transfers, automation and regulation enables us to provide you with a solution that is perfectly adapted to your needs.
We adapt to your expectations by providing you with numerous solutions for research laboratories or industrial production.
All our equipment is CE compliant and is manufactured with materials that comply with current legislation.
Caractéristiques (Fr) | Specifications (Eng) | |
---|---|---|
Atmosphère de travail* Process* |
Air Atmosphère contrôlée : Gaz neutre ou hydrogéné Sous vide (primaire ou secondaire) |
Air Controlled Atmosphere : neutral of hydrogenated gas Vacuum (medium and high) |
Température Maximale Maximum temperature |
Jusqu’à 1450°C |
Up to 1450°C |
Vitesse de chauffe/refroidissement maximale* Maximum Heating/cooling speed*
*En fonction du type d’éprouvette/tôle *Depending on the type of specimen/plate |
100°C/s |
100°C/s |
Trempe Quenching |
Sous gaz ou aspersion de fluide |
Under gas or fluid spraying |
Overshoot / undershoot Overshoot / undershoot |
± 5°C |
± 5°C |
Homogénéité thermique zone utile Thermal homogeneity of the useful area |
± 5°C |
± 5°C |
Transfert à chaud de l’échantillon vers zone de trempe Hot transfer of the specimen to the quenching zone |
< 2s |
< 2s
|
Volume utile Usable volume |
< 50L
|
< 50L
|
Autre dimensionnement Further sizing |
Sur consultation
|
Upon request |
Caractéristiques (Fr) | Specifications (Eng) | |
---|---|---|
Trempe (bain) Quenching |
Eau, huile, zinc Selon demande
|
Water, oil, zinc Further upon request |
Supervision Supervision |
IHM sur pc standard |
HCI on standard PC |
We are able to offer our clients an end-to-end approach thanks to our technical skills and the experience of our teams.
A unique and advanced technological solution dedicated to the oxidation phase involved in the manufacture of VCSELs